Products
Li-ion /Lead-acid battery
Operation: On-grid(5kW), Backup(3kW)
Charging and discharging(3kW)
Zero export to grid
U-disk for software updating
Without LCD, no risk of dust or water
Separate APP setting/monitoring
Wi-Fi/GPRS
Flexible local monitoring through APP, Pad or PC
Free communication choices through Wi-Fi, GPRS or RS485
Flexible monitor through Lantrun APP, Pad or PC
Fast trouble shooting through USB, webserver or Lantrun APP
Model Specifications | HSI-3600 | HSI-4600 | HSI-5000 |
Input Data (DC) | |||
Max. DC power | 3800W | 5000W | 5400W |
Max. DC voltage | 600V | ||
Start voltage | 100V | ||
DC nominal voltage | 360V | ||
PV voltage range | 100V-600V | ||
MPPT voltage range | 120V-550V | ||
Max. input current per string of tracker A/tracker B | 11A/11A | ||
Number of independent MPP inputs | 2 | ||
Output Data (AC) | |||
Nominal AC output power | 3600W | 4600W | 5000W |
Max. AC apparent power | 3600VA | 4600VA | 5000VA |
Max. output current | 16.4A | 21.0A | 22.8A |
AC nominal voltage; range | 220V/230V/240V; 180Vac-280Vac | ||
AC grid frequency; range | 50,60Hz;±5 Hz | ||
Power factor at rate power | 1 | ||
Power factor | 0.8leading…0.8lagging | ||
THDi | <3% | ||
AC connection | Single phase | ||
Battery | |||
Battery type | Li-ion or Lead-acid | ||
Norminal voltage | 51.2V | ||
Battery capacity | >=100Ah(depending requirement) | ||
Energy | 5.0kWh | ||
Max. discharging /charging power | 2500W / 2500W | ||
Charging curve | 3-stage adaptive with maintenance | ||
Operating voltage range | 46-57V | ||
Max. charging/discharging current | 50A / 50A | ||
Backup Output | |||
Output rate power | 2500W | ||
Output voltage | 230Vac ±2%, 50Hz (60Hz Optional)±0.2%, THDv<3%(linear load) | ||
Efficiency | |||
Max. efficiency | 97% | 97.10% | 97.10% |
Euro - eta | 96.50% | 96.50% | 96.50% |
MPPT efficiency | 99.50% | 99.50% | 99.50% |
Protection Devices | |||
DC reverse polarity protection | Yes | ||
DC switch rating for each MPPT | Yes | ||
Output over current protection | Yes | ||
Output overvoltage protection-varistor | Yes | ||
Ground fault monitoring | Yes | ||
Grid monitoring | Yes | ||
Integrated all - pole sensitive leakage current monitoring unit | Yes | ||
General Data | |||
Dimensions (W / H / D) | 495*420*165mm | ||
Weight | 24kg | 24kg | 24kg |
Operating temperature range | -25...+600C (-13...+ 1400F) With derating above 450C(1130F) | ||
Noise emission (typical) | ≤ 25 dB(A) | ||
Altitude | Up to 2000m(6560ft)Without power derating | ||
Relative humidity | 95% | ||
Consumption: operating (standby) / night | <5W / < 0.5 W | ||
Topology | Transformerless | ||
Cooling concept | Natural | ||
Environmental protection rating | IP65 | ||
Features | |||
DC connection | H4/MC4 | ||
AC connection | Screw terminal | ||
Display | LED | ||
Interfaces: Wi-Fi/USB/GPRS/RS485 | Yes/Yes/Opt/Opt | ||
Warranty: 5 years / 10 years / 15 years | Yes/Opt/Opt | ||
Certificates and approvals | CE,IEC 62109-1&2, VDE 0126-1-1,G83/2, AS4777&AS/NZS 3100 |